Company News
Installation and maintenance of stainless steel pneumatic sanitary clamp angle seat valve
view :
Clamp angle seat valves must comply with applicable safety regulations
1. The pipeline must be clean and free from pollution.
2. Install as needed, but with the actuator facing upwards. Pay attention to the flow direction.
3. When connecting the valve, pay attention to aligning it with the pipeline, and only remove the actuator when the user has special requirements.
Before opening or repairing the angle valve, cut off the fluid and control gas source, and reduce the pressure in the pipeline system.
Installation and maintenance of stainless steel pneumatic sanitary clamp angle seat valve
Stainless steel pneumatic sanitary clamp angle seat valve. Attention:
Characteristics when choosing flow direction A:
When selecting this flow direction, it can improve the service life of the product.
When the working medium is liquid, selecting this flow direction can prevent water hammer impact.
3. For products with diameters of Φ 15/Φ 20/Φ 25, the working pressure must be below 0.3MPa, otherwise a double acting actuator must be selected.
For products with a diameter of Φ 32/Φ 40, the actuator must be selected with a double acting diameter of Φ 100.
For products with a diameter of Φ 50, the actuator must be selected with a double acting size of Φ 125.